Retraction of the new coating from the
surface leaving voids. In this particular case
the previous coat consist of a solvent based
wax wood preservative over coated with a
white water based emulsion coating.
Possible Causes
Oil, grease, wax, moisture and or silicon
contamination or coatings on the surface
not permitting the surface to be wetted by
the subsequent coating.
Very smooth or polished surfaces which
does not provide for a mechanical key
How Can I Fix This Problem
Remove oil, grease, wax, moisture and /
or silicon contamination.
This is often very difficult and costly to
achieve with coal tar coatings on porous
substrates like wood and it might be
better to continue with the original coating/
treatment.
We do that the nature of the original coat
can be difficult to ascertain, and thus
finding an appropriate solution might
require some small scale experimentation.